chore: Repository cleanup - Remove unnecessary files #16
@@ -1,167 +0,0 @@
|
|||||||
# Quick Diagnostic: Why Hosts Weren't Talking
|
|
||||||
|
|
||||||
## The Problem
|
|
||||||
|
|
||||||
You were getting **empty MAC tables and no ping replies** when testing end-to-end connectivity between hosts. The root cause was **VLAN tagging mismatch** between hosts and leaf switches.
|
|
||||||
|
|
||||||
## The Mismatch Explained
|
|
||||||
|
|
||||||
### ❌ OLD Configuration (Broken)
|
|
||||||
|
|
||||||
**Hosts were sending untagged traffic:**
|
|
||||||
```yaml
|
|
||||||
host1:
|
|
||||||
exec:
|
|
||||||
- ip link add bond0 type bond mode balance-rr
|
|
||||||
- ip link set eth1 master bond0
|
|
||||||
- ip link set eth2 master bond0
|
|
||||||
- ip link set bond0 up
|
|
||||||
- ip addr add 10.40.40.101/24 dev bond0 # ← UNTAGGED traffic!
|
|
||||||
```
|
|
||||||
|
|
||||||
**Leaf switches expected VLAN-tagged traffic:**
|
|
||||||
```
|
|
||||||
interface Port-Channel1
|
|
||||||
switchport mode access
|
|
||||||
switchport access vlan 40 # ← Expecting tagged VLAN 40!
|
|
||||||
mlag 1
|
|
||||||
```
|
|
||||||
|
|
||||||
### Traffic Flow (Broken):
|
|
||||||
```
|
|
||||||
Host1 (untagged)
|
|
||||||
↓
|
|
||||||
eth1/eth2 (bonds)
|
|
||||||
↓
|
|
||||||
Leaf1 Port-Channel1 (access VLAN 40)
|
|
||||||
↓
|
|
||||||
Traffic dropped because VLAN doesn't match!
|
|
||||||
↗ No MAC learning
|
|
||||||
↗ No connectivity
|
|
||||||
```
|
|
||||||
|
|
||||||
---
|
|
||||||
|
|
||||||
## ✅ NEW Configuration (Fixed)
|
|
||||||
|
|
||||||
**Hosts now send VLAN-tagged traffic:**
|
|
||||||
```yaml
|
|
||||||
host1:
|
|
||||||
exec:
|
|
||||||
- ip link add bond0 type bond mode balance-rr
|
|
||||||
- ip link set eth1 master bond0
|
|
||||||
- ip link set eth2 master bond0
|
|
||||||
- ip link set bond0 up
|
|
||||||
# Create VLAN 40 subinterface
|
|
||||||
- ip link add link bond0 name bond0.40 type vlan id 40
|
|
||||||
- ip link set bond0.40 up
|
|
||||||
- ip addr add 10.40.40.101/24 dev bond0.40 # ← TAGGED traffic!
|
|
||||||
```
|
|
||||||
|
|
||||||
**Leaf switches expect VLAN-tagged traffic:**
|
|
||||||
```
|
|
||||||
interface Port-Channel1
|
|
||||||
switchport mode access
|
|
||||||
switchport access vlan 40 # ← Now matches!
|
|
||||||
mlag 1
|
|
||||||
```
|
|
||||||
|
|
||||||
### Traffic Flow (Fixed):
|
|
||||||
```
|
|
||||||
Host1 (VLAN 40 tagged)
|
|
||||||
↓
|
|
||||||
bond0.40 interface (sends tagged frames)
|
|
||||||
↓
|
|
||||||
eth1/eth2 (carries tagged traffic)
|
|
||||||
↓
|
|
||||||
Leaf1 Port-Channel1 (access VLAN 40)
|
|
||||||
↓
|
|
||||||
Frames untagged and placed in VLAN 40
|
|
||||||
↓
|
|
||||||
Switches forward in VLAN 40
|
|
||||||
↓
|
|
||||||
VXLAN encapsulation for remote VTEP
|
|
||||||
↓
|
|
||||||
✓ MAC learning works
|
|
||||||
✓ Connectivity established
|
|
||||||
```
|
|
||||||
|
|
||||||
---
|
|
||||||
|
|
||||||
## VLAN Tagging Mapping
|
|
||||||
|
|
||||||
| Host | Interface | VLAN Tag | Purpose | Test |
|
|
||||||
|------|-----------|----------|---------|------|
|
|
||||||
| host1 | bond0.40 | 40 | L2 VXLAN test | Ping host3 |
|
|
||||||
| host2 | bond0.34 | 34 | L3 VXLAN (VRF gold) VLAN | Ping host4 |
|
|
||||||
| host3 | bond0.40 | 40 | L2 VXLAN test | Ping host1 |
|
|
||||||
| host4 | bond0.78 | 78 | L3 VXLAN (VRF gold) VLAN | Ping host2 |
|
|
||||||
|
|
||||||
---
|
|
||||||
|
|
||||||
## Why This Works
|
|
||||||
|
|
||||||
### Layer 2 Switching Basics
|
|
||||||
|
|
||||||
When a **Linux host sends traffic on a VLAN subinterface** (e.g., `bond0.40`):
|
|
||||||
1. The interface **adds a VLAN tag (802.1Q)** to the Ethernet frame
|
|
||||||
2. Frame contains: `[Dest MAC][Source MAC][**VLAN Tag (40)**][Type][Data]`
|
|
||||||
|
|
||||||
When a **Leaf switch receives the tagged frame**:
|
|
||||||
1. It reads the VLAN tag (40)
|
|
||||||
2. The frame matches the port's access VLAN (40)
|
|
||||||
3. Frame is **untagged** and forwarded in VLAN 40
|
|
||||||
4. Switch learns MAC and floods/forwards appropriately
|
|
||||||
|
|
||||||
---
|
|
||||||
|
|
||||||
## Testing the Fix
|
|
||||||
|
|
||||||
```bash
|
|
||||||
# 1. Verify host VLAN interface exists
|
|
||||||
docker exec clab-arista-evpn-fabric-host1 ip -d link show bond0.40
|
|
||||||
# Expected: vlan protocol 802.1Q id 40 <BROADCAST,MULTICAST,UP,LOWER_UP>
|
|
||||||
|
|
||||||
# 2. Verify host has IP on VLAN interface
|
|
||||||
docker exec clab-arista-evpn-fabric-host1 ip addr show bond0.40
|
|
||||||
# Expected: inet 10.40.40.101/24 dev bond0.40
|
|
||||||
|
|
||||||
# 3. Ping the gateway (virtual router on Leaf)
|
|
||||||
docker exec clab-arista-evpn-fabric-host1 ping -c 1 10.40.40.1
|
|
||||||
# Expected: Should get reply from leaf VLAN40 gateway
|
|
||||||
|
|
||||||
# 4. Ping remote host
|
|
||||||
docker exec clab-arista-evpn-fabric-host1 ping -c 4 10.40.40.103
|
|
||||||
# Expected: 4/4 packets successful
|
|
||||||
```
|
|
||||||
|
|
||||||
---
|
|
||||||
|
|
||||||
## Key Files Changed
|
|
||||||
|
|
||||||
1. **evpn-lab.clab.yml**
|
|
||||||
- Updated all 4 host definitions with VLAN subinterface configuration
|
|
||||||
- Each host now creates and configures its own VLAN tagged interface
|
|
||||||
|
|
||||||
2. **END_TO_END_TESTING.md** (new)
|
|
||||||
- Comprehensive testing guide for all connectivity scenarios
|
|
||||||
- Troubleshooting procedures
|
|
||||||
- Expected results validation
|
|
||||||
|
|
||||||
---
|
|
||||||
|
|
||||||
## Why VLAN Tagging is Required Here
|
|
||||||
|
|
||||||
The topology uses **access mode port-channels on leafs** because:
|
|
||||||
|
|
||||||
1. **Each host has a single VLAN** (no trunk needed)
|
|
||||||
2. **VLAN tagging from the host side** is cleaner than reconfiguring leaf ports
|
|
||||||
3. **Matches production design** where hosts are single-VLAN attached
|
|
||||||
4. **Avoids manual leaf reconfiguration** after deployment
|
|
||||||
|
|
||||||
Alternative approach (NOT used):
|
|
||||||
- Could change leaf port-channels to trunk mode
|
|
||||||
- Would require manually configuring allowed VLANs
|
|
||||||
- More complex and less automated
|
|
||||||
|
|
||||||
This is the automated, repeatable approach that avoids manual post-deployment configuration.
|
|
||||||
Reference in New Issue